Back to all Specifications








Print

SPECIFICATION SHEET– Tilt Panel Repaint (over Waterbased) – Exterior – Semi Gloss

REF NUMBER: LSPECR465
SPECIFICATION FOR: Repaint
COATING FINISH: Semi Gloss
SUBSTRATE: Tilt Panels


APPLICATION DATA SHEET NO. THEORETICAL SPREADING RATE DRY FILM THICKNESS RECOAT TIME DATASHEET MSDS

FIRST COAT

Sunshield Semi Gloss

Apply by brush, roller or airless spray

LP0009 14m2/L 30 Microns 2 hours Download Download

SECOND COAT

Sunshield Semi Gloss

Apply by brush, roller or airless spray

LP0009 14m2/L 30 microns 2 hours Download Download

CHARACTERISTICS OF SUBSTRATE

Tilt up and precast concrete is a major building method for medium and large structures. Most structures require painting with conventional or textured coatings for both long-term protection and aesthetics. Tilt up concrete should be cured for a minimum 6 weeks before painting. Almost all tilt up panels have bond breaker compounds used on them which requires complete removal prior to coating. Use an appropriate bond breaker remover according to label instructions allowing 48 hours drying prior to coating. Patch any defects with suitable filling compounds and remove any surplus surface protrusions.


SURFACE PREPARATION

Ensure previous coating system is in sound condition and firmly adherent to the substrate. High pressure wash (pressure 1500 to 2500 psi) to ensure surface is clean and free from contaminants such as dust, mould and mildew. If any contaminants are found, they must be cleaned with appropriate products as per label instructions. High pressure cleaning will also test the integrity of the previous coating to gauge the level of preparation required. If peeling and/or flaking is present, remove failed coating back to bare substrate and follow new work specification for spot priming. Spot prime any bare areas as per new work specification sheet.


ADDITIONAL INFORMATION

Drying times are approximate at 25° C and 50% relative humidity. Allow longer drying times under cool, moist or low air movement conditions. Spreading rates will vary from the quoted theoretical rates depending on application methods and surrounding conditions.
Do not paint if temperatures are below 10°C or likely to fall below 10°C during drying period
Refer to TECHNICAL DATA SHEETS for additional information.



DATE OF ISSUE: 26-Mar-2012


Disclaimer: The Luxury Paints Online Specification System offers generic coating specifications which are based on general painting conditions. Certain factors including spreading rates, substrate condition etc could affect the performance or appearance of a coating system and may vary between individual projects. In the case of a situation or condition not mentioned in this current system please email info@luxurypaints.com.au to request a custom specification.

The information provided in the Luxury Paints Online Specification System is intended as guide only and is correct at the time of printing. It is valid for a period of twelve (12) months from the date of issue. Each specification should be read in conjunction with all relevant Technical Data sheets and Safety Data sheets and it is the responsibility of the reader to check this information prior to recommending the specification system to ensure that it is suited for the intended purpose.

Luxury Paints recommends that the online system should be used as a master reference for all new specifications. Printed copies of specification sheets should be cross referenced with the online system prior to issuing to ensure validity. Luxury Paints does not take responsibility for printed hardcopy specifications that have expired.

 
Menu