Back to all Specifications








Print

SPECIFICATION SHEET– Compressed Fibre Cement – Exterior – Low Sheen

REF NUMBER: LSPEC0035
SPECIFICATION FOR: New
COATING FINISH: Low Sheen
SUBSTRATE: Compressed Fibre Cement


APPLICATION DATA SHEET NO. THEORETICAL SPREADING RATE DRY FILM THICKNESS RECOAT TIME DATASHEET MSDS

FIRST COAT

Speedprep

Apply by brush, roller or airless spray

LP0001 8m2/L 30 Microns 2 hours Download Download

SECOND COAT

Sunshield Low Sheen

Apply by brush, roller or airless spray

LP0008 14m2/L 30 microns 2 hours Download Download

THIRD COAT

Sunshield Low Sheen

Apply by brush, roller or airless spray

LP0008 14m2/L 30 microns 2 hours Download Download

CHARACTERISTICS OF SUBSTRATE

*OPTIONAL:
FIRST COAT
Sunshield Low Sheen: Apply one thin coat (25 microns) followed by second and third coats as above.

(Sunshield Low Sheen is self priming to fibre cement, brick, masonry, render and most timber substrates. Aged, grey hardwood as well as tannin rich timbers should be primed with Multi Purpose Undercoat. Non-ferrous metals should be suitably prepared and primed. Sunshield Gloss neutral base is not self-priming.)

Compressed fibre cement may be presented as sheeting or moulded objects being high density usually affixed externally to metal or timber framing with expressed joints. Compressed fibre cement sheeting must be installed in accordance with the manufacturer�s instructions.


SURFACE PREPARATION

Ensure sheeting is installed as per manufactures instruction. Clean surface to ensure its is free from any contaminants such as dust, mould and mildew. Please ensure the removal off all dust which is best achieved with a stiff bristled broom.


ADDITIONAL INFORMATION

Drying times are approximate at 25° C and 50% relative humidity. Allow longer drying times under cool, moist or low air movement conditions. Spreading rates will vary from the quoted theoretical rates depending on application methods and surrounding conditions.
Do not paint if temperatures are below 10°C or likely to fall below 10°C during drying period
Refer to TECHNICAL DATA SHEETS for additional information.



DATE OF ISSUE: 17-Mar-2012


Disclaimer: The Luxury Paints Online Specification System offers generic coating specifications which are based on general painting conditions. Certain factors including spreading rates, substrate condition etc could affect the performance or appearance of a coating system and may vary between individual projects. In the case of a situation or condition not mentioned in this current system please email info@luxurypaints.com.au to request a custom specification.

The information provided in the Luxury Paints Online Specification System is intended as guide only and is correct at the time of printing. It is valid for a period of twelve (12) months from the date of issue. Each specification should be read in conjunction with all relevant Technical Data sheets and Safety Data sheets and it is the responsibility of the reader to check this information prior to recommending the specification system to ensure that it is suited for the intended purpose.

Luxury Paints recommends that the online system should be used as a master reference for all new specifications. Printed copies of specification sheets should be cross referenced with the online system prior to issuing to ensure validity. Luxury Paints does not take responsibility for printed hardcopy specifications that have expired.

 